Сензори за температура и трансмитери
Температурни сензори
PROBE WITHOUT MOUNTING APPLIANCES |
SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body – stainless steel Nr.1.4571 Cable – Heat-resistant, metal PWM – Heat-resistant, silikone insulation – With PVC insulation |
R – 1 x Pt100 DIN IEC 751 2R – 2 x Pt100 DIN IEC 751 |
t1 0 … 60°C t2 0 … 200°C t3 –50 … 200°C t4 0 … 400°C |
n = 30, 50, 100,
|
|
J – Fe-CuNi DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
|||
K – NiCr-Ni DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
ANGLE-TYPE BODY PROBE WITHOUT MOUNTING APPLIANCES |
SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body – stainless steel Nr.1.4571 Cable – Heat-resistant, metal PWM – Heat-resistant, silikone insulation – With PVC insulation |
R – 1 x Pt100 DIN IEC 751 2R – 2 x Pt100 DIN IEC 751 |
t1 0 … 60°C t2 0 … 200°C t3 –50 … 200°C t4 0 … 400°C |
n = 30, 50, 100,
|
|
J – Fe-CuNi DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
|||
K – NiCr-Ni DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
MOISTURE-PROOF SCREW-IN TYPE PROBE |
SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body – stainless steel Nr.1.4571 Cable – Heat-resistant, metal PWM – Heat-resistant, silikone insulation – With PVC insulation |
R – 1 x Pt100 DIN IEC 751 2R – 2 x Pt100 DIN IEC 751 |
t1 0 … 60°C t2 0 … 200°C t3 –50 … 200°C t4 0 … 400°C |
n = 30, 50, 100, 150, 200, 300 mm G = 3/8”, ¼”, M8, M10, M12, M14, M16 Other dimensions are possible too |
|
J – Fe-CuNi DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
|||
K – NiCr-Ni DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
PROBE FOR LIQUID MEDIA | SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body – stainless steel Nr.1.4571 Cable – Heat-resistant, metal PWM – Heat-resistant, silikone insulation – With PVC insulation |
R – 1 x Pt100 DIN IEC 751 |
t1 0 … 60°C t2 0 … 200°C t3 –50 … 200°C t4 0 … 400°C |
n = 12 ... 40 mm
|
|
J – Fe-CuNi DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
|||
K – NiCr-Ni DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
BAYONET-TYPE PROBE | SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body – stainless steel Nr.1.4571 Cable – Heat-resistant, metal PWM – Heat-resistant, silikone insulation – With PVC insulation |
R – 1 x Pt100 DIN IEC 751 |
t1 0 … 60°C t2 0 … 200°C t3 –50 … 200°C t4 0 … 400°C |
n = 12 ... 40 mm
|
|
J – Fe-CuNi DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
|||
K – NiCr-Ni DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
NEEDLE PROBE WITH HANDLE | SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body |
R – 1 x Pt100 DIN IEC 751 |
t1 0 … 60°C t3 –50 … 200°C t4 0 … 400°C |
K = max 6000 mm |
|
J – Fe-CuNi DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
|||
K – NiCr-Ni DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
PROBE WITH PROTECTION HEAD |
SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body |
R – 1 x Pt100 DIN IEC 751 2R–2 x Pt100 DIN IEC 751 |
t1 0 … 60°C t2 0 … 200°C t3–50 …200°C t4 0 … 400°C |
n = 50, 100, 150, 300, 500, 1000, 1500 mm G = 3/8”, ¼”, ½”, 1”,M12, M14, M16, M18, M20 Other dimensions are possible too |
|
J – Fe-CuNi DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
|||
K – NiCr-Ni DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
PROBE WITH PROTECTION HEAD FOR EXTREME TEMPERATURES |
SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body |
R – 1 x Pt100 DIN IEC 751 2R–2 x Pt100 DIN IEC 751 |
t1 0 … 60°C t2 0 … 200°C t3–50 …200°C t4 0 … 400°C |
n = 50, 100, 150, 300, 500, 1000, 1500 mm G = 3/8”, ¼”, ½”, 1”,M12, M14, M16, M18, M20 Other dimensions are possible too |
|
J – Fe-CuNi DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
|||
K – NiCr-Ni DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
PROBE WITH PROTECTION HEAD AND REPLACEABLE INSERT |
SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body |
R – 1 x Pt100 DIN IEC 751 2R–2 x Pt100 DIN IEC 751 |
t1 0 … 60°C t2 0 … 200°C t3–50 …200°C t4 0 … 400°C |
n = 50, 100, 150, 300, 500, 1000, 1500 mm G = 3/8”, ¼”, ½”, 1”,M12, M14, M16, M18, M20 Other dimensions are possible too |
|
J – Fe-CuNi DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
|||
K – NiCr-Ni DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
PROBE WITH PROTECTION HEAD AND REPLACEABLE INSERT |
SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body |
R – 1 x Pt100 DIN IEC 751 2R–2 x Pt100 DIN IEC 751 |
t1 0 … 60°C t2 0 … 200°C t3–50 …200°C t4 0 … 400°C |
n = 50, 100, 150, 300, 500, 1000, 1500 mm G = 3/8”, ¼”, ½”, 1”,M12, M14, M16, M18, M20 Other dimensions are possible too |
|
J – Fe-CuNi DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
|||
K – NiCr-Ni DIN IEC 584 |
t1 0 … 60°C t4 0 … 400°C |
PROBE WITH CERAMIC TUBE |
SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body |
S –Pt10Rh-Pt DIN IEC 584 |
t7 0 … 1200°C t8 0 … 1500°C |
n = 170, 240 mm d = 10, 14 mm m = 100 … 1000 mm |
|
t7 0 … 1200°C | ||||
K – NiCr-Ni DIN IEC 584 |
ANGLE-TYPE THERMOCOUPLE |
SENSITIVE ELEMENT |
TEMPERATURE RANGE |
DIMENSIONS | ![]() |
Body |
J – Fe-CuNi DIN IEC 584 |
t4 0 … 400°C t5 0 … 600°C |
n = 300 …1000 mm m = 100 … 1000mm Other dimensions are possible too |
|
K – NiCr-Ni DIN IEC 584 |
t4 0 … 400°C t6 0 … 1000°C t7 0 … 1200°C |
|||
S – t10Rh-Pt DIN IEC 584 |
t7 0 … 1200°C t8 0 … 1500°C |
REPLACEBLE INSERT | SENSITIVE ELEMENT |
RANGE | SIZE | ![]() |
Body |
R – 1 x Pt100 DIN IEC 751 2R – 2 x Pt100 DIN IEC 751 |
t2 0 … 200°C t3–50 … 200°C t4 0 … 400°C |
n = 50, 150, 300, 500 mm d = 5, 6, 8, 10 Other dimensions are possible too |
|
J – Fe-CuNi DIN IEC 584 |
t4 0 … 400°C t5 0 … 600°C |
|||
K – NiCr-Ni DIN IEC 584 |
t4 0 … 400°C t6 0 … 1000°C |
REPLACEBLE INSERT | SENSITIVE ELEMENT |
RANGE | SIZE | ![]() |
Body |
R – 1 x Pt100 DIN IEC 751 2R – 2 x Pt100 DIN IEC 751 |
t2 0 … 200°C t3–50 … 200°C t4 0 … 400°C |
n = 50, 150, 300, 500 mm d = 5, 6, 8 Other dimensions are possible too |
|
J – Fe-CuNi DIN IEC 584 |
t4 0 … 400°C t5 0 … 600°C |
|||
K – NiCr-Ni DIN IEC 584 |
t4 0 … 400°C t6 0 … 1000°C |
MANTEL THERMOCOUPLE | SENSITIVE ELEMENT |
RANGE | SIZE | ![]() |
Body – stainless steel Nr.1.4571 With mineral isolation |
K – NiCr-Ni DIN IEC 584 |
T9 0 … 1100°C For air media |
n = 50 ... 1500mm Other dimensions are possible too |
|
MANTEL THERMOCOUPLE WITH CABLE |
SENSITIVE ELEMENT |
RANGE | SIZE | ![]() |
Body – stainless steel Nr.1.4571 With mineral insulation Cable – Heat-resistant, metal overbraid – With PVC isolation |
K – NiCr-Ni DIN IEC 584 |
T9 0 … 1100°C For air media |
n = 12 ... 40 mm Other dimensions are possible too |
|